CONTACT US

Hangzhou Civit Instrument Equipment Co., Ltd.
Address: Room A215, No.10 Xiyuan Road, Sandun, Xihu District, Hangzhou City, Zhejiang Province, China  
Tel: 0086-571-28202862
Fax: 0086-571-87272769
Mobile: 0086-13588310953
Email: sales@civittest.com
Product > Concrete Testing > Concrete Thermophysical Parameter Measurement System

PRODUCT DETAILS

Concrete Thermophysical Parameter Measurement System  HR-6


I. USE

Using microprocessors and imported instruments to collect various signals and data, automatically and quickly process various parameters of concrete to achieve the purpose of measurement and control. Therefore, the measurement and control system conforms to the national standard. The equipment has the characteristics of high speed, accuracy and automation. It can be widely used in various fields of construction, construction and scientific research.

The test system can be used to measure four concrete physical parameters, such as concrete specific heat parameters, concrete thermal conductivity, concrete thermal conductivity, and concrete adiabatic temperature rise

II. Feature

1. adopt the thermal balance air medium temperature adjustment system, the thermal inertia of the system is small, and the adjustment precision is high.

2. The refrigeration unit adopts secondary control, and can continuously and stepssly adjust the cooling output in a large range.

3. The heating unit is an electronically controlled heating element, with stepless smooth adjustment and good followability.

4. The temperature measurement element adopts high-precision PT100 platinum resistance, which forms a temperature measurement and control network in a special form, with automatic temperature compensation function, high temperature measurement accuracy, stability and reliability.

5. This device combines the advantages of digital intelligent PID direct control instrument and microcomputer to form a two-stage temperature measurement and control system, which can ensure the long-term stable operation of the instrument.

6. The device provides abundant graphical test data post-processing software. In this system, graph and curve fitting wiring, specific heat data solution and thermal conductivity calculation can be easily and efficiently completed, and color graphs and text reports can be output. high-precision and high-reliability measurements.


Adiabatic temperature rise of concrete:

Number

Name

Technical indicators

1

Temperature range

10-80

2

Temperature solution

0.01

3

Temperature accuracy

0.05

4

Tracking temperature

0.1

5

The volume of the specimen barrel

50L

6

Power supply

220V


Concrete thermal conductivity:

Number

Name

Technical indicators

1

Temperature control accuracy

≤±0.5

2

Appearance size of the instrument

Hot water bucket Φ500×800mm

3

Cold water bucket

Φ500×925mm

4

Specimen size

Φ200×8400m




Specific heat of concrete:


Number

Name

Technical indicators

1

Temperature control accuracy

≤±0.1

2

The volume of the specimen barrel

Φ240×480mm

3

Specimen size

Φ200×400mm

4

Specimen size

Φ200×8400m


Concrete heat conduction


Number

Name

Technical indicators

1

Temperature measurement

0~100

2

Temperature solution

0.01

3

Temperature accuracy

0.1

4

Specimen size

Φ200×400m

5

Loading voltage

DC 0-100V, 500W

6

Power supply

AC220 ± 10%

7

Instrument weight

200Kg

8

Use environmental conditions

Temperature 20

10

Relative humidity

<80%